UPS Buying Guide - Waveform First, Runtime Last

Quick answer

Buy on waveform, not runtime. An active PFC power supply - most servers, desktops and NAS units - can shut down unexpectedly on a stepped wave, so a pure sine unit is the spec gate. The cheapest pure sine unit we track is $191.43. Size by watts, never VA. And the data cable matters more than the battery.

Prices updated · 66 units tracked · 13 tower, 36 rackmount

Pure sine wave units in stock

40 in-stock listings · every row here states pure sine output in its own listing · VA, watts, waveform and outlet counts are the maker’s claims, read from the listing · refreshed every few hours

UnitVAWattsWaveformFormCommsPrice
APC SMT750C
APC Smart-UPS, SMT750C Tower Back-UPS, 750 VA Backup Battery Power Supply, 6 x
750 VA500 Wpure sineTowerUSB, Serial, SNMP, LCD$529.60Buy Now
APC SMX750C
APC Network UPS, 750VA Smart-UPS Sine Wave UPS with Extended Run Option, SMX75
750 VA600 Wpure sineRackmountnot stated$499.99Buy Now
APC BR1000MS
APC UPS 1000VA/600W Pure Sine Wave UPS for Computer, Electronics, BR1000MS
1000 VA600 Wpure sinenot statedUSB, LCD$191.43Buy Now
CyberPower PR1000LCDRT1U
CyberPower PR1000LCDRT1U Smart App Sinewave UPS Battery Backup and Surge Prote
1000 VA800 Wpure sineRackmountSNMP, LCD$530.76Buy Now
APC SMT1500RM2U
APC Smart-UPS RM SMT1500RM2U 1000W/1440VA 2U Rackmount LCD UPS System (Renewed
1440 VA1000 Wpure sineRackmountUSB, LCD$499.00Buy Now
APC SMT1500RM2U
APC MAIN-62525 Smart-UPS RM SMT1500RM2U 1000W/1440VA 2U Rackmount LCD UPS Syst
1440 VA1000 Wpure sineRackmountUSB, LCD$512.68Buy Now
Eaton Eaton-1440VA
Eaton Electrical - 5P1500RTG2 - Eaton 5P Gen2 5P1500RTG2 1440VA Rack/Tower UPS
1440 VAnot statedpure sineRackmountnot stated$959.83Buy Now
Eaton OMNIVS1500LCD
Eaton Tripp Lite OMNIVS1500LCD 1500VA UPS 900W 8 Outlets 5ft Extension Cord
1500 VA900 Wpure sineTowernot stated$198.18Buy Now
APC BR1500MS2
APC UPS 1500VA/900W Pure Sine Wave UPS for Computer, Electronics, BR1500MS2
1500 VA900 Wpure sinenot statedLCD$299.99Buy Now
APC APC-1500VA
APC 1500VA/900W Back-UPS Pro Pure Sinewave UPS for Gaming PC, Xbox Series X
1500 VA900 Wpure sinenot statedUSB$306.99Buy Now
Eaton SMART1500PSGLCD
Eaton Tripp Lite SMART1500PSGLCD Pure Sine Wave 1500VA Gaming UPS 900W
1500 VA900 Wpure sinenot statedLCD$315.99Buy Now
APC APC-1500VA
APC 1500VA/900W Back-UPS Pro Pure Sinewave UPS for Gaming PC, Xbox Series X
1500 VA900 Wpure sinenot statedUSB$316.99Buy Now
APC SMC1500C
APC 1500VA Smart Standing UPS Battery Backup with SmartConnect | Sinewave, AVR
1500 VAnot statedpure sinenot statedUSB$399.00Buy Now
APC SMC1500C
APC Smart-UPS 1500VA/900W Line Interactive UPS with SmartConnect, SMC1500C
1500 VA900 Wpure sinenot statednot stated$569.99Buy Now
APC SMC1500C
APC 1500VA Smart UPS with SmartConnect, SMC1500C Sinewave UPS Battery Backup,
1500 VA900 Wpure sinenot statednot stated$600.00Buy Now
Vertiv Vertiv-1500VA
Vertiv Liebert PSI5-1500MT120 1500VA UPS 120V Battery Backup AVR Mini Tower
1500 VA1350 Wpure sineTowernot stated$605.58Buy Now
APC SMC1500
APC Smart-UPS 1500VA/900W Rackmount UPS, Line Interactive, SMC1500-2UC
1500 VA900 Wpure sineRackmountnot stated$790.50Buy Now
APC SMC1500
APC 1500VA Smart UPS with SmartConnect, Rack Mount UPS Battery Backup, Sinewav
1500 VA100 Wpure sineRackmountUSB$795.50Buy Now
Eaton SMC15002URM
Eaton Tripp Lite SMC15002URM 1500VA Pure Sine Wave 2U Rack Mount UPS 1000W
1500 VA1000 Wpure sineRackmountUSB, LCD$801.10Buy Now
Vertiv Vertiv-1500VA
Vertiv Liebert PSI5-1500RT120 1500VA Battery Backup UPS Pure Sine Wave AVR
1500 VA1350 Wpure sineRackmountLCD$749.99Buy Now
Eaton Eaton-1500VA
Eaton Tripp Lite SMART1500RMXL2U 1500VA UPS Extend Run Online Option 1440W
1500 VA1440 Wpure sineRackmountSNMP, LCD$625.97Buy Now
Eaton Eaton-1500VA
Eaton Tripp Lite SMART1500RM2U SmartPro 1500VA Pure Sine Wave UPS 1350W AVR
1500 VA1350 Wpure sineRackmountUSB, SNMP, LCD$859.95Buy Now
APC SMX1500RM2UNC
APC Network UPS, 1500VA Smart-UPS Sine Wave UPS with Extended Run Option, SMX1
1500 VA1200 Wpure sineRackmountSNMP$993.00Buy Now
APC SMX1500RM2UC
APC Network UPS, 1500VA Smart-UPS Sine Wave UPS with Extended Run Option, SMX1
1500 VA1200 Wpure sineRackmountnot stated$637.22Buy Now
Eaton Eaton-1500VA
Eaton Tripp Lite SMART1500RM2UN SmartPro 1500VA UPS Network Card 1350W AVR
1500 VA1350 Wpure sineRackmountSNMP, LCD$1329.95Buy Now
CyberPower PR1500RTXL2UN
CyberPower PR1500RTXL2UN Smart App Sinewave UPS System, 1500VA/1500W, 8 Outlet
1500 VA1500 Wpure sineRackmountSNMP, LCD$1350.00Buy Now
CyberPower CyberPower-1500VA
CyberPower OL1500RTXL2U Smart App Online UPS System, 1500VA/1350W, 8 Outlets,
1500 VA1350 Wpure sineRackmountLCD$1395.95Buy Now
Eaton Eaton-1500VA
Eaton Tripp Lite SU1500RTXLCDN 1500VA Online Double-Conversion UPS 1350W
1500 VA1350 Wpure sineTowerUSB, Serial, LCD$1499.95Buy Now
APC SMT1500RM2UCNC
APC 1500VA Smart UPS with SmartConnect and Network Card, SMT1500RM2UCNC, Rackm
1500 VA1000 Wpure sineRackmountSNMP$1099.99Buy Now
Vertiv Vertiv-1500VA
Vertiv Liebert PSI5-1500RT120LIN Lithium-Ion UPS 1500VA AVR 2U w/ RDU120
1500 VA1350 Wpure sineRackmountSNMP$1794.99Buy Now
CyberPower PR2200RTXL2UN
CyberPower PR2200RTXL2UN Smart App Sinewave UPS System, 2200VA/2200W, 8 Outlet
2200 VA2200 Wpure sineRackmountSNMP, LCD$1094.22Buy Now
APC SMT2200RM2UC
APC 2200VA Smart UPS with SmartConnect, SMT2200RM2UC Rack Mount UPS Battery Ba
2200 VA1980 Wpure sineRackmountnot stated$1012.38Buy Now
CyberPower PR2200RT2U
CyberPower PR2200RT2U Smart App Sinewave UPS System, 2200VA/2200W, 8 Outlets,
2200 VA2200 Wpure sineRackmountLCD$1485.00Buy Now
CyberPower PR2200LCD
CyberPower PR2200LCD Smart App Sinewave UPS System, 2200VA/1980W, 10 Outlets,
2200 VA1980 Wpure sineTowerSNMP, LCD$1759.95Buy Now
APC SMT3000RM2UC
APC 3000VA UPS SMT3000RM2UC Rack Mount Sinewave Battery Backup Bundle
3000 VA2700 Wpure sineRackmountnot stated$1840.50Buy Now
APC APC-3000VA
APC 3000VA Lithium Ion UPS, SMTL3000RM2UC, Pure Sine Wave Rackmount UPS, 120V
3000 VA2700 Wpure sineRackmountLCD$1999.00Buy Now
Eaton Eaton-3000VA
Eaton Tripp Lite SU3000RTXLCD2U 3000VA Online Double-Conversion UPS 2700W
3000 VA2700 Wpure sineTowerUSB, Serial, LCD$2309.95Buy Now
APC SMX3000RMLV2U
APC Network UPS, 3000VA Smart-UPS Sine Wave UPS with Extended Run Option, SMX3
3000 VA2700 Wpure sineRackmountnot stated$2493.71Buy Now
Eaton Eaton-3000VA
Eaton Tripp Lite Series 3000VA Smart UPS Back Up, Sine Wave, Network Card Incl
3000 VA2700 Wpure sineRackmountLCD$2749.00Buy Now
APC APC-3000VA
APC Smart-UPS 3000 VA Lithium Ion UPS, SMTL3000RMUCNC, Short Depth, Pure Sine
3000 VA2700 Wpure sineRackmountSNMP, LCD$4055.60Buy Now
Units that do not state a waveform (26) - unknown is not the same as safeshow

These listings do not say what they output. That silence is not neutral evidence. Across the units we track, 40 state pure sine and none states simulated - because pure sine is a thing makers advertise and a stepped approximation is a thing they leave out. So the honest reading of a blank is “find out before you buy”, not “probably fine”. Check the manufacturer’s own datasheet for the model, not the retail listing.

Waveform not stated in the listing

26 in-stock listings · VA, watts, waveform and outlet counts are the maker’s claims, read from the listing · refreshed every few hours

UnitVAWattsWaveformFormCommsPrice
APC BE550G
APC UPS 550VA/330W Backup Battery Power Supply for PC, Electronics, BE550G
550 VA330 Wnot statednot statednot stated$101.33Buy Now
APC BE650G1
APC UPS 650VA/390W Battery Backup & Surge Protector for PC, NAS | BE650G1
650 VA390 Wnot statednot statednot stated$94.97Buy Now
APC SMT750
APC Smart-UPS 750 VA Tower UPS - 750VA/500W - 4.6 Minute Full Load - 6 x NEMA
750 VA500 Wnot statedTowernot stated$449.00Buy Now
APC APC-750VA
APC SMART-UPS 750VA LCD 230V with SMARTCONNECT
750 VA500 Wnot statedTowerUSB, SNMP, LCD$499.99Buy Now
Eaton Eaton-850VA
Eaton Tripp Lite ECO850LCD 850VA UPS 425W Battery Backup Surge Protector
850 VA425 Wnot statedTowernot stated$130.10Buy Now
Eaton 5P1500R
Eaton 5P 1500 RACKMOUNT - UPS - 1100 Watt - 1440 VA (5P1500R) -
1440 VA1100 Wnot statedRackmountnot stated$1182.07Buy Now
APC APC-1500VA
APC UPS 1500VA/900W Battery Backup for PCs, Office Electronics, BX1500M
1500 VA900 Wnot statednot statednot stated$189.99Buy Now
Eaton OMNI1500LCDT
Eaton Tripp Lite OMNI1500LCDT 1500VA UPS 810W 10 Outlets 650 Joules AVR LCD
1500 VA810 Wnot statedTowerLCD$239.67Buy Now
Eaton Eaton-1500VA
Eaton Tripp Lite ECO1500LCD 1500VA UPS 900W Battery Backup Surge Protector
1500 VA900 Wnot statednot statedUSB$254.13Buy Now
Eaton SMART1500LCD
Eaton Tripp Lite SMART1500LCD 1500VA 2U Rack Mount UPS 900W Battery Backup
1500 VA900 Wnot statedRackmountLCD$290.00Buy Now
Eaton SMART1500LCDT
Eaton Tripp Lite SMART1500LCDT 1500VA UPS 900W 10 Outlets 650 Joules AVR
1500 VA900 Wnot statedTowerLCD$311.05Buy Now
Eaton SMX1500LCDT
Eaton Tripp Lite SMX1500LCDT 230V 1500VA UPS 900W 8 Outlets AVR LCD
1500 VA900 Wnot statednot statedLCD$249.99Buy Now
Eaton SMART1500LCDTXC
Eaton Tripp Lite SMART1500LCDTXC 1500VA UPS Extended Run 1000W 10 Outlets
1500 VA1000 Wnot statednot statedLCD$590.83Buy Now
Eaton Eaton-1500VA
Eaton 5P rackmount Compact 1500VA UPS
1500 VA1100 Wnot statedRackmountUSB, Serial$949.95Buy Now
Tripp Lite Tripp Lite-1500VA
Tripp Lite SUINT1500LCD2U 1500VA 1350W Ups Smart Online Intl LCD Rackmount 208
1500 VA1350 Wnot statedRackmountUSB, LCD$1184.40Buy Now
Eaton Eaton-1500VA
Eaton Tripp Lite SUINT1500LCD2U 230V 1500VA Double-Conversion UPS 1350W
1500 VA1350 Wnot statedRackmountLCD$1215.66Buy Now
Vertiv Vertiv-1500VA
Vertiv Liebert PSI5-1500RM1201UN 1500VA UPS Battery Backup AVR 1U w/ RDU120
1500 VA1350 Wnot statedRackmountnot stated$1297.24Buy Now
Eaton Eaton-1500VA
EATON 5PX G2 1500VA 1500W 208V LINE-Interactive UPS - 8 C13 OUTLETS, CYBERSECU
1500 VA1500 Wnot statednot statednot stated$1342.27Buy Now
Vertiv Vertiv-1500VA
Vertiv - GXT5-1500IRT2UXL - Vertiv Liebert GXT5 UPS - 1500VA/1500W 230V | Onli
1500 VA1500 Wnot statedRackmountLCD$1555.99Buy Now
Vertiv Vertiv-1500VA
Vertiv Liebert GXT5 Lithium-Ion Online UPS 1500VA/1350W 120V Tower/Rack UPS (G
1500 VA1350 Wnot statedTowernot stated$2456.05Buy Now
Vertiv Vertiv-1500VA
Vertiv Liebert GXT5 Lithium-Ion N Online UPS 1500VA/1350W 120V Tower/Rack UPS
1500 VA1350 Wnot statedTowernot stated$2699.99Buy Now
APC SMT3000RM2UC
APC 3000VA Smart UPS with SmartConnect, SMT3000RM2UC Rack Mount UPS Battery Ba
3000 VA2700 Wnot statedRackmountUSB, Serial$1820.00Buy Now
Eaton Eaton-3000VA
Eaton Tripp Lite SU3000LCD2UHV 208V/230V 3000VA Double-Conversion UPS 2700W
3000 VA2700 Wnot statednot statedLCD$2204.33Buy Now
APC SMX3000RMLV2U
APC Smart-UPS X SMX3000RMLV2U 3000 VA Rack-mountable UPS. SMART UPS X 3000VA R
3000 VA2700 Wnot statedRackmountLCD$2381.99Buy Now
Vertiv Vertiv-3000VA
Vertiv Liebert PSI5-3000SRT120LI Lithium-Ion UPS 3000VA Battery Backup 2U
3000 VA2700 Wnot statedRackmountnot stated$2494.99Buy Now
Vertiv Vertiv-5000VA
Vertiv Liebert GXT5-192VBATKIT Double Conversion UPS 5000VA to 10kVA 192V
5000 VA1350 Wnot statednot statednot stated$1716.00Buy Now
How many listings actually tell you the waveform

Of the 66 in-stock units we track, 40 state an output waveform - 61%. Of those, 40 say pure sine and 0 say simulated. The remaining 26 say nothing at all.

The asymmetry is the finding. Pure sine is a selling point and gets printed; a stepped approximation is not and does not. So a silent listing is more likely to be the cheaper waveform than the better one, and we still do not claim to know which - we count it as unknown and tell you to check the datasheet.

VA is not watts, and this is the sizing error people actually make

Sellers lead with VA because it is the bigger number. VA is apparent power; watts is real power, and watts is what decides whether your load fits. The ratio between them is the unit’s power factor and it is not a constant - Synology’s own guidance is that “Different manufacturers have different volt-ampere (VA) ratings based on the performance of their UPS. To determine the total power (W) that the UPS can support, we recommend consulting the manufacturer’s product manual.”

Their published method, which is the one these pages use rather than one of our own:

Output power required = total wattage of your devices / output power factor of the UPS

Synology’s worked example takes a 650 W load and a UPS with a 70% output power factor and arrives at 928.5 W - so a “1000VA” unit rated at 600 W would not have carried it, despite the reassuring four-digit number on the box. Add your own devices’ figures from their spec sheets; we publish no wattage on your behalf.

What each VA band actually delivers

This is a measurement of our own shelf, not a recommendation ladder and not a table of what your hardware draws. Each row is the range of maker-stated real power across the units we have in stock in that band. Your load is your own number - it is on your device’s spec sheet under power consumption, and we do not publish it for you.

VA bandUnits in stockMaker-stated wattsFromPure sine / not stated
600-900VA7330-600 W$94.972 / 5
1000-1500VA44100-1500 W$189.9928 / 16
1500VA and up151350-2700 W$1012.3810 / 5

Watt figures are what each seller states. Two units with the same VA rating routinely state different watts, which is the entire reason the next section exists.

A UPS with a dead battery is a surge protector

The sealed lead-acid battery inside a typical unit has an expected service life of three to five years, per APC’s own guidance, and heat is the dominant factor in cutting that short. When it goes, nothing on the front panel necessarily changes - the unit keeps filtering and keeps passing mains through. It simply stops doing the one job you bought it for, silently, and you find out during the outage.

Replacement cartridges for common consumer and small-business units are widely reported at roughly $30-50. That is a reported range and not our measurement: we do not track UPS battery prices, and we are not going to publish a figure we have not measured as though we had. Check the current price of the specific cartridge your model takes before you treat it as the cheap option.

The practical consequence for buying: the purchase price is not the cost. A unit bought today gets one battery included and then wants another one somewhere around year four, for as long as you keep it. And whichever unit you buy, Synology’s instruction is the one worth following - “simulate a power outage to ensure the function performs as expected” - because the only proof the whole chain works is watching it work.

The spec gate: Active PFC needs a sine wave

Almost every decision on this page collapses into one question, and it is not how many minutes of runtime you get. It is whether the unit puts out a sine wave. Modern power supplies - in servers, in desktops, in most NAS units built in the last decade - use active power factor correction. An active PFC supply does not draw current smoothly across the mains cycle; it watches the incoming waveform and shapes its draw against it. Give it a waveform that is not a sine wave and the circuit that does the watching can misread what it is looking at.

CyberPower define the compatibility feature in their own glossary as a UPS characteristic that "delivers sine wave output to prevent unexpected shutdowns or component stress for connected devices with Active PFC power supplies." Read that failure mode again, because it is the one that matters: an unexpected shutdown. Not a warning light, not degraded runtime. The machine goes off. It goes off at the exact moment the UPS switched to battery, which is the exact moment you bought the UPS to survive.

This is why the table above defaults to pure sine only and puts everything else behind a labelled disclosure. It is not an attempt to hide cheaper inventory - the counts are stated in the open and one click shows every row. It is that the default view of a page about power protection should not put a unit in front of a server buyer that may drop the server the first time the mains flickers.

The stepped or simulated wave is not a defective product. It is a cheaper inverter design that outputs a coarse approximation of a sine wave, and for a router, an access point, a network switch or a simple desktop with a passive supply it is entirely adequate and costs meaningfully less. The mistake is not buying one. The mistake is buying one for the machine you actually care about, on the assumption that a UPS is a UPS.

Why a blank waveform field is the worst answer

When we seeded this category we counted something worth stating plainly. Of the in-stock units we verified, a clear majority of those that say anything at all say pure sine. The number that state a simulated or stepped wave is zero. Not a small number - zero.

That is not because the simulated-wave units have vanished from the market. It is because pure sine output is a feature worth printing on a box and a stepped approximation is a thing you leave out of the bullet list. The silence is doing work.

So we render three states rather than two, and we do not collapse the third into either of the others. A listing that states pure sine is marked pure sine. A listing that states simulated is marked simulated. A listing that says nothing is marked not stated, in amber, and it stays that way until somebody finds a datasheet. We will not fill that cell in by inference in either direction: guessing pure sine would sell somebody a shutdown, and guessing simulated would be inventing a fact about hardware we have not tested.

What to do about it as a buyer is simple and slightly tedious. Take the model number to the manufacturer's own product page - not the retail listing, not a review, the maker's specification sheet - and look for the output waveform line. It is nearly always there. If it is not there either, that absence is now a real data point rather than a gap in a retail description, and the safe reading of it is to assume the cheaper design.

Sizing, without any number we made up

The other thing people get wrong is sizing, and the trap is built into how these products are marketed. The number on the front of the box is volt-amperes. The number that determines whether your equipment fits is watts. They are not the same number and the ratio between them is not fixed across makers.

Synology's own guidance says this outright, and we quote it rather than paraphrase because paraphrasing is where a caveat gets lost: "Different manufacturers have different volt-ampere (VA) ratings based on the performance of their UPS. To determine the total power (W) that the UPS can support, we recommend consulting the manufacturer's product manual."

Their published method is a single division. Add up the real wattage of everything you are going to plug in, then divide by the UPS's output power factor, and the result is the output power the unit needs to be rated for. Their worked example takes a 650 W load and a unit with a 70% output power factor and lands on 928.5 W - which means a box proudly labelled 1000VA, if it happens to be rated at 600 W, does not carry that load at all.

We do not supply your load figure. There is no table on this site of what a four-bay NAS draws or what a 2U server draws, and there is not going to be one until we have fetched and logged a maker datasheet for each machine. A wattage attributed to "typical" hardware is not a citation. Your own device publishes its power consumption in its specifications, usually under an environment or general heading, and that number - not ours - is the one to divide.

The one thing our own catalogue can tell you honestly is what is on the shelf at each VA band and what real power those units claim. That is a measurement of our inventory, it is labelled as one in the table above, and it is deliberately not dressed up as a recommendation about your hardware.

The battery is a consumable and it fails quietly

A UPS is the rare purchase where the thing you bought stops working without telling you. The sealed lead-acid battery inside a typical unit has an expected service life of roughly three to five years according to APC's own guidance, and heat shortens it - a unit in a warm cupboard ages faster than the same unit in a cool rack.

When that battery reaches the end of its life, the front panel does not necessarily change. The unit still filters, still regulates, still passes mains straight through to the outlets. Everything looks normal. It has simply become an expensive surge protector, and you discover this during the outage rather than before it.

Replacement cartridges for common small-business units are widely reported around the $30-50 mark. We label that as reported rather than measured because we do not track UPS battery prices and we are not going to publish a number we have not checked as though we had. Look up the specific cartridge your model takes before you count on the cheap-repair path.

Whatever you buy, the test is worth doing on day one, and the instruction comes from a vendor rather than from us. Synology's compatibility page tells readers that the power-off function varies by brand and model and to simulate a power outage to confirm it behaves as expected. Pull the plug deliberately, while you are watching, on a day when nothing is at stake. A shutdown chain that has never been tested is a shutdown chain you are guessing about.

Tower or rackmount, and the depth question nobody asks first

Form factor looks like the easy decision and is where the returns come from. A tower unit sits on the floor, takes a standard wall outlet, and does not care about your rack. A rackmount unit occupies 1U or 2U, bolts in, and puts the weight where the rest of the equipment already is - which matters, because these units are heavy and the weight is nearly all battery.

The trap on the rackmount side is depth rather than height. Racks vary, and a great many home and small-office racks are shallower than the full-depth cabinets these units were designed for. A 2U unit that is 26 inches deep does not fit a rack with 20 inches of usable depth, and the U count in the product title tells you nothing about that. Where a listing states its depth we render it; where it does not, it does not, and measuring your rack before ordering is not optional.

The second rackmount consideration is the plug. Larger units frequently ship with a NEMA 5-20P plug rather than the ordinary 5-15P, which is a physically different plug with a rotated blade and will not go into a standard household outlet. Where a listing states its plug type we show it as that listing's statement of what it ships with. What we do not do anywhere on this site is tell you what circuit to install. That is an electrician's decision and a code question, and the gap between "this unit ships with a 5-20P plug" and "go and put in a 20-amp circuit" is the gap between a fact and a liability.

What a UPS is for, which is not what most people think

It is worth being blunt about the job, because the marketing has trained everybody to shop for the wrong metric. Runtime is the headline number and it is close to irrelevant for the machine most readers of this site are protecting.

A file server does not need to keep serving files through a two-hour outage. It needs enough time to notice the power has gone, finish what it is writing, flush its caches, unmount its volumes and shut down cleanly. That is a job measured in a couple of minutes, not hours. What kills an array is not the outage; it is being switched off mid-write, repeatedly, until something in the metadata does not survive it.

Which means the signalling matters more than the battery. A UPS with a big battery and no data cable to the machine is a delay, not a protection: it postpones the ungraceful shutdown by twenty minutes and then delivers it anyway. A UPS with a modest battery and a USB cable that the operating system actually recognises will save the array. The comms column in the table above is there because it is the column that does the work.

That is also why we publish no runtime figures of our own. Runtime is a function of load, battery age and temperature, and we measure none of the three. Where a seller states a runtime we render it as that seller's claim attached to that seller's listing, and we never aggregate those claims into a number that looks like ours.

Where to go next

UPS for a NAS covers the shutdown integration in DSM, QTS and TrueNAS and what Synology’s tested list does and does not tell you · UPS for a server rack is the rackmount case, including the depth trap · tower vs rackmount compares the two on price and on what each actually costs you · 600-900VA units · 1000-1500VA units · 1500VA and up units · NAS devices and used servers are the machines on the other end of the cable · enclosures and 10GbE gear are the rest of what shares the outlet.

Frequently asked questions

Do I actually need a pure sine wave UPS?

If the machine has an active PFC power supply - which covers most servers, most desktops built in the last decade and most NAS units - then yes, and the failure mode is specific. CyberPower's own definition of Active PFC compatibility describes sine wave output as the feature that prevents "unexpected shutdowns or component stress" on such devices. An unexpected shutdown at the moment of transfer to battery is the precise event you bought the unit to avoid. For a router, a switch or an access point, a stepped-wave unit is fine and costs less.

What is the difference between VA and watts on a UPS?

VA is apparent power and it is the bigger number, which is why it goes on the box. Watts is real power and it is what decides whether your load fits. The ratio between them is the unit's output power factor and it varies by manufacturer. Synology's guidance is to consult the manufacturer's manual for the watt figure rather than infer it, and to size by dividing your total load in watts by that power factor.

How do I work out what size UPS I need?

Add up the real wattage of every device you will plug in, taken from each device's own specification sheet, then divide that total by the UPS's output power factor. Synology's worked example divides a 650 W load by a 70% power factor and arrives at 928.5 W of required output. We do not publish per-device wattage figures on this site because we have not sourced them per device; the figure for your machine is on your machine's spec sheet.

Why do some listings not say whether they output a sine wave?

Because pure sine output is a selling point and a stepped approximation is not. Across the in-stock units we track, a large share state pure sine and none states simulated - sellers who have the better waveform print it and sellers who do not stay quiet. We mark those listings as not stated rather than guessing in either direction, and the practical step is to look the model up on the manufacturer's own datasheet, where the output waveform is nearly always specified.

How long does a UPS battery last, and what does replacing it cost?

APC's own guidance puts the expected service life of the sealed lead-acid battery in a typical unit at three to five years, with operating temperature the dominant factor in shortening it. Replacement cartridges for common consumer and small-business models are widely reported at roughly $30-50, though that is a reported range rather than a figure we track. The important part is that a dead battery is silent: the unit keeps filtering and passing mains through, so it looks fine until the outage.

Does the UPS need to talk to my server, or is the battery enough?

It needs to talk to it. A battery without a data connection buys you a delay and then gives you the same ungraceful shutdown twenty minutes later. The connection - USB on most small units, SNMP or a network card on larger ones - is what lets the machine notice the outage, flush its writes, unmount its volumes and stop cleanly. For a storage array that is the entire value of the purchase, and it is why the comms column matters more than the runtime claim.

Will a rackmount UPS fit my rack?

Check the depth, not the U count. Many home and small-office racks are shallower than the full-depth cabinets these units are designed for, and a 2U label tells you nothing about how far back the unit extends. Also check the plug: larger units often ship with a NEMA 5-20P, which is physically different from a standard 5-15P outlet. We render both facts where a listing states them, and we give no guidance about your building's wiring - that is an electrician's question.

WHAT THIS PAGE DOES NOT PUBLISH

We publish no runtime figure, no per-device wattage and no electrical-code guidance. Runtime claims are rendered as the seller's own words against the listing that made them; the sizing method below is Synology's published formula with your load as the input; plug types are what a listing says the unit ships with, never a recommendation about your wiring.

Sources

Specification claims on this page were checked against the pages below on 4 August 2026. Where a widely-repeated figure did not survive that check, we report what the source says now and say so in the text rather than repeating the familiar number.

  1. CyberPower Systems - Active PFC Compatibility (glossary) (cyberpowersystems.com, 2026-08-20)
    Used for: the maker's own definition, quoted verbatim on our pages: Active PFC compatibility is "a feature of UPS systems that delivers sine wave output to prevent unexpected shutdowns or component stress for connected devices with Active PFC power supplies." This is the source for the spec-gate framing - the failure mode named by the maker is an unexpected shutdown, which is precisely the event a UPS was bought to prevent.
  2. Synology Inc. - How do I choose a suitable UPS? (Knowledge Center) (kb.synology.com, 2026-08-20)
    Used for: the sizing method used on these pages, quoted rather than paraphrased: "Output power = Total wattage of your devices / Output power factor of a UPS", with Synology's own worked example dividing a 650 W load by a 70% power factor to reach 928.5 W. Also the VA-versus-watts caveat in the vendor's own words: "Different manufacturers have different volt-ampere (VA) ratings based on the performance of their UPS. To determine the total power (W) that the UPS can support, we recommend consulting the manufacturer's product manual." Article last updated 1 April 2024.
  3. Synology Inc. - Products Compatibility List - UPS, filtered to tested by Synology (synology.com, 2026-08-20)
    Used for: the full tested list, captured in a rendered browser session: 79 entries, 73 UPS units and 6 management cards or protocol adapters. Also the vendor's own two operational notes, which we quote rather than restate: that any listed model can extend UPS service to a second Synology product over the network, and that "The UPS power-off function varies by brand and model. Please simulate a power outage to ensure the function performs as expected." The list is CATEGORY-level: it does not filter per machine.
  4. QNAP Systems - Configuring the UPS settings, QTS 5.2.x (docs.qnap.com, 2026-08-20)
    Used for: that QTS supports three connection modes - USB cable, SNMP over the network, and network UPS slave against another machine acting as the server - and the two configurable responses to a power failure: powering off after a set period, or entering auto-protection mode, which stops services and unmounts volumes.
  5. Network UPS Tools project - Network UPS Tools (NUT) - project overview and hardware compatibility list (networkupstools.org, 2026-08-20)
    Used for: the project's own description of its scope - "to provide support for Power Devices, such as Uninterruptible Power Supplies, Power Distribution Units, Automatic Transfer Switches, Power Supply Units and Solar Controllers" - its GPL licence, and the size of its hardware compatibility list at the date read: at least 199 manufacturers and 1,436 device models. We link this list; we do not reproduce it. It is maintained upstream, it changes, and a stale copy of somebody else's compatibility list is worse than a link to the live one.
  6. Schneider Electric (APC) - What is the expected life of my APC UPS VRLA battery? (se.com, 2026-08-20)
    Used for: the three-to-five-year expected service life of the sealed lead-acid battery in a typical APC UPS, and that operating temperature is the dominant factor in shortening it. The replacement-cartridge prices quoted on our pages are described as reported figures, not as our measurement - we do not track UPS battery prices.
  7. DatacenterDisk - Live catalogue - UPS listings (datacenterdisk.com, 2026-08-20)
    Used for: every price, VA rating, watt rating, outlet count and waveform statement on these pages, read from the seller's own title and feature bullets at seed time and refreshed by the price cron. The waveform coverage rate is recomputed on each render rather than frozen here.
Share:WhatsAppFacebookPost on X