UPS for a NAS - the Cable Matters More Than the Battery

Quick answer

A NAS does not need to ride out the outage. It needs two or three minutes to flush its writes, unmount its volumes and stop cleanly - so the data connection is the feature, not the runtime. Pick a pure sine unit with USB, confirm your NAS sees it, then pull the plug deliberately and watch it work.

Prices updated · 17 units in stock state USB signalling

Synology’s tested UPS list: sourced, and narrower than it looks

We read Synology’s own compatibility list in a rendered session on 2026-08-20. It is operable and we captured it in full: 79 entries, of which 73 are UPS units and 6 are management cards or protocol adapters rather than a UPS. The list itself.

Two things about it that change how you should read a badge. First, it is a category-level list, not a per-machine one. Passing a machine model to the page does not filter it. So VENDOR-LISTED here means “Synology has tested this unit with Synology products”, never “with your DS923+”, and we will not imply the stronger claim.

Second, and this is the number that matters for a US buyer: 17 of the 73 tested units carry a regional SKU suffix - -TW, -CH, -JP, -CN, IEC - meaning they were built for other mains supplies. Synology lists Back-UPS Pro BR1500MS-TW; the US shelf carries BR1500MS2. Those are different SKUs. We match on the exact base part number and refuse the substring rule that would badge one as the other, so our match count against a US catalogue is honestly low: 2 of 66 units we track.

Read that low number correctly. It is a statement about which SKUs Synology chose to test, not a verdict on the units we stock. NOT LISTED means untested by Synology; it does not mean incompatible, and the overwhelming majority of these units talk to a NAS over USB through the same generic HID power-device protocol.

Pure sine units with USB signalling, in stock

12 in-stock listings · badged against Synology's tested list - exact base part number, never a substring match · VA, watts, waveform and outlet counts are the maker’s claims, read from the listing · refreshed every few hours

UnitVAWattsWaveformFormCommsPrice
APC SMT750C
APC Smart-UPS, SMT750C Tower Back-UPS, 750 VA Backup Battery Power Supply, 6 x
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
750 VA500 Wpure sineTowerUSB, Serial, SNMP, LCD$529.60Buy Now
APC BR1000MS
APC UPS 1000VA/600W Pure Sine Wave UPS for Computer, Electronics, BR1000MS
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1000 VA600 Wpure sinenot statedUSB, LCD$191.43Buy Now
APC SMT1500RM2U
APC Smart-UPS RM SMT1500RM2U 1000W/1440VA 2U Rackmount LCD UPS System (Renewed
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1440 VA1000 Wpure sineRackmountUSB, LCD$499.00Buy Now
APC SMT1500RM2U
APC MAIN-62525 Smart-UPS RM SMT1500RM2U 1000W/1440VA 2U Rackmount LCD UPS Syst
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1440 VA1000 Wpure sineRackmountUSB, LCD$512.68Buy Now
APC APC-1500VA
APC 1500VA/900W Back-UPS Pro Pure Sinewave UPS for Gaming PC, Xbox Series X
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1500 VA900 Wpure sinenot statedUSB$306.99Buy Now
APC APC-1500VA
APC 1500VA/900W Back-UPS Pro Pure Sinewave UPS for Gaming PC, Xbox Series X
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1500 VA900 Wpure sinenot statedUSB$316.99Buy Now
APC SMC1500C
APC 1500VA Smart Standing UPS Battery Backup with SmartConnect | Sinewave, AVR
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1500 VAnot statedpure sinenot statedUSB$399.00Buy Now
APC SMC1500
APC 1500VA Smart UPS with SmartConnect, Rack Mount UPS Battery Backup, Sinewav
VENDOR-LISTED · Synology tested
1500 VA100 Wpure sineRackmountUSB$795.50Buy Now
Eaton SMC15002URM
Eaton Tripp Lite SMC15002URM 1500VA Pure Sine Wave 2U Rack Mount UPS 1000W
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1500 VA1000 Wpure sineRackmountUSB, LCD$801.10Buy Now
Eaton Eaton-1500VA
Eaton Tripp Lite SMART1500RM2U SmartPro 1500VA Pure Sine Wave UPS 1350W AVR
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1500 VA1350 Wpure sineRackmountUSB, SNMP, LCD$859.95Buy Now
Eaton Eaton-1500VA
Eaton Tripp Lite SU1500RTXLCDN 1500VA Online Double-Conversion UPS 1350W
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1500 VA1350 Wpure sineTowerUSB, Serial, LCD$1499.95Buy Now
Eaton Eaton-3000VA
Eaton Tripp Lite SU3000RTXLCD2U 3000VA Online Double-Conversion UPS 2700W
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
3000 VA2700 Wpure sineTowerUSB, Serial, LCD$2309.95Buy Now

1 of these 12 rows match Synology’s tested list exactly.

USB units that do not state a waveform

5 in-stock listings · check the maker's datasheet before buying one of these for a machine with an active PFC supply · VA, watts, waveform and outlet counts are the maker’s claims, read from the listing · refreshed every few hours

UnitVAWattsWaveformFormCommsPrice
APC APC-750VA
APC SMART-UPS 750VA LCD 230V with SMARTCONNECT
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
750 VA500 Wnot statedTowerUSB, SNMP, LCD$499.99Buy Now
Eaton Eaton-1500VA
Eaton Tripp Lite ECO1500LCD 1500VA UPS 900W Battery Backup Surge Protector
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1500 VA900 Wnot statednot statedUSB$254.13Buy Now
Eaton Eaton-1500VA
Eaton 5P rackmount Compact 1500VA UPS
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1500 VA1100 Wnot statedRackmountUSB, Serial$949.95Buy Now
Tripp Lite Tripp Lite-1500VA
Tripp Lite SUINT1500LCD2U 1500VA 1350W Ups Smart Online Intl LCD Rackmount 208
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
1500 VA1350 Wnot statedRackmountUSB, LCD$1184.40Buy Now
APC SMT3000RM2UC
APC 3000VA Smart UPS with SmartConnect, SMT3000RM2UC Rack Mount UPS Battery Ba
NOT LISTED · not on Synology's tested list - which is a statement about Synology's testing, not about the unit
3000 VA2700 Wnot statedRackmountUSB, Serial$1820.00Buy Now
How many listings actually tell you the waveform

Of the 66 in-stock units we track, 40 state an output waveform - 61%. Of those, 40 say pure sine and 0 say simulated. The remaining 26 say nothing at all.

The asymmetry is the finding. Pure sine is a selling point and gets printed; a stepped approximation is not and does not. So a silent listing is more likely to be the cheaper waveform than the better one, and we still do not claim to know which - we count it as unknown and tell you to check the datasheet.

What the NAS actually does when the power goes

Every NAS operating system worth running has the same three-stage response and it is worth knowing before you shop, because it tells you which specification to care about. Stage one: the UPS reports that mains has failed. Stage two: a countdown, either a fixed period you set or a wait until the UPS reports low battery. Stage three: the NAS stops services, unmounts its volumes and powers down cleanly.

The whole sequence is a couple of minutes. It is not a strategy for staying online through an outage, and treating it as one is how people end up buying four times the battery they need. A NAS that shuts down cleanly at minute three has fully succeeded. A NAS with a two-hour battery and no data cable has fully failed, just later.

Synology's implementation lives in Control Panel under Hardware and Power, and their own documentation describes the choice as either a custom delay or waiting until low battery, after which the unit enters Safe Mode. QNAP's QTS exposes the same shape under External Device, with two configurable responses to a power failure: power off after a set period, or enter auto-protection mode, which their documentation describes as stopping all services and unmounting all volumes to protect your data. TrueNAS runs its UPS service on Network UPS Tools and exposes master and slave modes so one machine can watch the UPS and the rest can watch that machine.

The practical consequence: if you already run TrueNAS, or a Linux box, or anything else that can run NUT, then the vendor compatibility list is much less binding than it looks, because NUT talks to a very large number of units directly.

NUT, and why we link it instead of reproducing it

Network UPS Tools is the open-source project that most of this ecosystem quietly rests on. In the project's own words its goal is "to provide support for Power Devices, such as Uninterruptible Power Supplies, Power Distribution Units, Automatic Transfer Switches, Power Supply Units and Solar Controllers", offering a common protocol and set of tools across manufacturers' incompatible ones. It is GPL licensed.

Its hardware compatibility list is the reference document for this question. At the date we read it, it recorded at least 199 manufacturers and 1,436 device models as known compatible - a very different number from any single NAS vendor's tested list.

We link that list rather than reproducing it, and the reason is a rule we apply generally: a stale copy of somebody else's compatibility list is worse than a link to the live one. It is maintained upstream, it changes, and a reader who checks our snapshot from months ago and finds their model missing has been actively misled by us. Go to the source: it is the single most useful page on this subject and it is not ours.

The practical route for most people is simpler than the list suggests. Plug the unit into the NAS by USB, open the UPS settings, and see whether the machine reports a battery. Most modern units present themselves through a generic HID power-device interface and are recognised without any configuration at all. If it appears, you are done. If it does not, the compatibility list is where to look next.

Sizing for a NAS, and the honest gap in it

The sizing method is the one on the hub page and it comes from Synology rather than from us: total the real wattage of everything on the UPS, then divide by the unit's output power factor to get the output rating you need. Synology's worked example puts a 650 W total against a 70% power factor and arrives at 928.5 W.

What we cannot give you is the first number. This site publishes no per-device wattage - not for a four-bay NAS, not for an eight-bay, not for a switch - because we have not fetched and logged a maker datasheet for each machine, and a wattage attributed to a typical device of that shape is not a citation. Your NAS publishes its own figure. On Synology's spec pages it sits under power consumption, usually with two values, one for access and one for hibernation, and a note about the drive configuration it was measured with. That last part matters: the figure moves with how many drives you have fitted, because most of the draw is spinning platters, not the chassis.

Two additions people forget. Drives spinning up simultaneously at power-on draw substantially more than they do at idle, so a unit sized exactly to the running figure has no headroom for a restart. And the network switch between the NAS and everything else needs to be on the same UPS, or the NAS survives the outage in perfect isolation and nobody can reach it.

What our own catalogue can tell you is what is on the shelf at each VA band and what real power those units claim - that table is on the hub, it is a measurement of our inventory, and it is labelled as one rather than dressed up as a recommendation about your hardware.

One UPS, several machines

The common homelab shape is one UPS carrying a NAS, a switch, and one or two other machines, and the question is how the machines that do not hold the USB cable find out about the outage.

All three ecosystems solve it the same way, with different names. Synology's compatibility page states it plainly: any model on their list can extend UPS service to a second Synology product using Network UPS Server, where the first machine connects by USB and relays the information to clients on the local network. QNAP exposes network UPS master and slave modes. TrueNAS calls it master and slave and, being NUT underneath, will happily act as either against a non-TrueNAS peer.

Because they are all speaking the same underlying protocol, mixed environments generally work: a TrueNAS box holding the cable can signal a Linux machine running NUT, and a Synology acting as server can be watched by another Synology. What is not guaranteed is any particular cross-vendor pairing, and we are not going to assert one we have not tested.

Synology adds one hardware caveat worth repeating because it catches people: connect the USB device directly to a USB port on the product. Connecting through a hub is not supported. If your NAS is behind a hub for want of ports, that is the first thing to eliminate when it fails to see the UPS.

Test it, because nobody else will

This is the step that gets skipped and it is the only one that proves the purchase worked. The instruction is not ours - it is on Synology's own compatibility page, attached to the tested list: the UPS power-off function varies by brand and model, so simulate a power outage to ensure the function performs as expected.

Do it deliberately, on a day when nothing is at stake, with nothing important being written. Pull the mains plug on the UPS - not the switch, the plug - and watch. The NAS should log the loss within seconds, count down, and shut down. Then restore power and confirm it comes back up and remounts cleanly.

Repeat it after any change to the chain: a new UPS battery, a firmware update on either device, moving the cable to a different port. And repeat it when the battery is around three years old, because a battery that has aged out will still let the NAS see the UPS and report a healthy state right up until the moment it is asked to actually supply power.

A shutdown chain that has never been tested is a shutdown chain you are guessing about, and the outage is a bad time to find out that the guess was wrong.

Where to go next

The UPS hub has the waveform rule and the sizing method in full · Rackmount units if the NAS lives in a rack · NAS devices and drive compatibility by machine cover the other end of the cable · NAS drives and filling a NAS are the array itself · enclosures share the outlet and want counting into the load.

Frequently asked questions

Does my UPS have to be on Synology's compatibility list?

No, and the list is narrower than most readers assume. It is category-level rather than per-machine, and a large share of the tested units are regional SKUs built for other mains supplies - Synology lists BR1500MS-TW where the US shelf carries BR1500MS2. Not listed means Synology has not tested that exact SKU; it is not a compatibility verdict. Most modern units present a generic HID power-device interface over USB and are recognised without configuration.

How much runtime does a NAS need?

Minutes, not hours. The job is to notice the outage, stop services, unmount volumes and power down cleanly, which takes a couple of minutes on a normal array. Buying a much larger battery to keep serving files through an outage is a different and much more expensive goal, and it only works if the network switch and everything else in the path are on the same protection.

Can one UPS shut down more than one machine?

Yes. One machine holds the USB cable and relays the state to the others over the network. Synology calls it Network UPS Server, QNAP calls it network UPS master and slave, and TrueNAS calls it master and slave. All three are speaking Network UPS Tools underneath, which is why mixed setups usually work - though we do not assert any specific cross-vendor pairing we have not tested.

Can I plug the UPS into my NAS through a USB hub?

Synology's own guidance says no - connect USB devices directly to a USB port on the Synology product, because connecting via a hub is not supported. If a NAS cannot see a UPS that is otherwise working, a hub in the path is the first thing to eliminate.

What is NUT and do I need it?

Network UPS Tools is the open-source project that provides a common protocol for monitoring power devices across manufacturers, licensed under the GPL. You do not install it on a Synology or QNAP - it is already underneath the vendor's UPS feature. You do use it directly on TrueNAS, Linux and BSD machines. Its hardware compatibility list recorded at least 199 manufacturers and 1,436 models at the date we read it, which is a far broader set than any single NAS vendor's tested list.

How do I know the shutdown actually works?

Test it, and take the instruction from the vendor rather than from us: Synology's compatibility page says the power-off function varies by brand and model and to simulate a power outage to ensure it performs as expected. Pull the mains plug deliberately, on a quiet day, and watch the NAS notice, count down and stop. Repeat after any firmware or hardware change, and again when the battery is a few years old.

Sources

Specification claims on this page were checked against the pages below on 4 August 2026. Where a widely-repeated figure did not survive that check, we report what the source says now and say so in the text rather than repeating the familiar number.

  1. CyberPower Systems - Active PFC Compatibility (glossary) (cyberpowersystems.com, 2026-08-20)
    Used for: the maker's own definition, quoted verbatim on our pages: Active PFC compatibility is "a feature of UPS systems that delivers sine wave output to prevent unexpected shutdowns or component stress for connected devices with Active PFC power supplies." This is the source for the spec-gate framing - the failure mode named by the maker is an unexpected shutdown, which is precisely the event a UPS was bought to prevent.
  2. Synology Inc. - How do I choose a suitable UPS? (Knowledge Center) (kb.synology.com, 2026-08-20)
    Used for: the sizing method used on these pages, quoted rather than paraphrased: "Output power = Total wattage of your devices / Output power factor of a UPS", with Synology's own worked example dividing a 650 W load by a 70% power factor to reach 928.5 W. Also the VA-versus-watts caveat in the vendor's own words: "Different manufacturers have different volt-ampere (VA) ratings based on the performance of their UPS. To determine the total power (W) that the UPS can support, we recommend consulting the manufacturer's product manual." Article last updated 1 April 2024.
  3. Synology Inc. - Products Compatibility List - UPS, filtered to tested by Synology (synology.com, 2026-08-20)
    Used for: the full tested list, captured in a rendered browser session: 79 entries, 73 UPS units and 6 management cards or protocol adapters. Also the vendor's own two operational notes, which we quote rather than restate: that any listed model can extend UPS service to a second Synology product over the network, and that "The UPS power-off function varies by brand and model. Please simulate a power outage to ensure the function performs as expected." The list is CATEGORY-level: it does not filter per machine.
  4. QNAP Systems - Configuring the UPS settings, QTS 5.2.x (docs.qnap.com, 2026-08-20)
    Used for: that QTS supports three connection modes - USB cable, SNMP over the network, and network UPS slave against another machine acting as the server - and the two configurable responses to a power failure: powering off after a set period, or entering auto-protection mode, which stops services and unmounts volumes.
  5. Network UPS Tools project - Network UPS Tools (NUT) - project overview and hardware compatibility list (networkupstools.org, 2026-08-20)
    Used for: the project's own description of its scope - "to provide support for Power Devices, such as Uninterruptible Power Supplies, Power Distribution Units, Automatic Transfer Switches, Power Supply Units and Solar Controllers" - its GPL licence, and the size of its hardware compatibility list at the date read: at least 199 manufacturers and 1,436 device models. We link this list; we do not reproduce it. It is maintained upstream, it changes, and a stale copy of somebody else's compatibility list is worse than a link to the live one.
  6. Schneider Electric (APC) - What is the expected life of my APC UPS VRLA battery? (se.com, 2026-08-20)
    Used for: the three-to-five-year expected service life of the sealed lead-acid battery in a typical APC UPS, and that operating temperature is the dominant factor in shortening it. The replacement-cartridge prices quoted on our pages are described as reported figures, not as our measurement - we do not track UPS battery prices.
  7. DatacenterDisk - Live catalogue - UPS listings (datacenterdisk.com, 2026-08-20)
    Used for: every price, VA rating, watt rating, outlet count and waveform statement on these pages, read from the seller's own title and feature bullets at seed time and refreshed by the price cron. The waveform coverage rate is recomputed on each render rather than frozen here.
Share:WhatsAppFacebookPost on X