A 2U label describes height, not depth, and depth is what stops the unit fitting a short home rack. Server power supplies are active PFC almost without exception, so pure sine is the gate here rather than a preference. Rackmount units start at $290.00 in our catalogue. Mount it at the bottom - it is mostly battery.
Prices updated · 36 rackmount units in stock · 25 state a NEMA plug type
The table below carries VA, watts, waveform, form factor and comms because those are what the listings state. It does not carry a depth column, because most listings do not state a depth and a column that is three quarters blank is worse than no column. Measure your rack, then check the specific model on the maker’s datasheet. And where a NEMA plug appears below it is what the listing says the unit ships with - it is not, and never is on this site, guidance about your building’s wiring.
26 in-stock listings · the class server power supplies want · VA, watts, waveform and outlet counts are the maker’s claims, read from the listing · refreshed every few hours
| Unit | VA | Watts | Waveform | Form | Comms | Price | |
|---|---|---|---|---|---|---|---|
APC SMX750C APC Network UPS, 750VA Smart-UPS Sine Wave UPS with Extended Run Option, SMX75 | 750 VA | 600 W | pure sine | Rackmount | not stated | $499.99 | Buy Now |
CyberPower PR1000LCDRT1U CyberPower PR1000LCDRT1U Smart App Sinewave UPS Battery Backup and Surge Prote | 1000 VA | 800 W | pure sine | Rackmount | SNMP, LCD | $530.76 | Buy Now |
APC SMT1500RM2U APC Smart-UPS RM SMT1500RM2U 1000W/1440VA 2U Rackmount LCD UPS System (Renewed | 1440 VA | 1000 W | pure sine | Rackmount | USB, LCD | $499.00 | Buy Now |
APC SMT1500RM2U APC MAIN-62525 Smart-UPS RM SMT1500RM2U 1000W/1440VA 2U Rackmount LCD UPS Syst | 1440 VA | 1000 W | pure sine | Rackmount | USB, LCD | $512.68 | Buy Now |
Eaton Eaton-1440VA Eaton Electrical - 5P1500RTG2 - Eaton 5P Gen2 5P1500RTG2 1440VA Rack/Tower UPS | 1440 VA | not stated | pure sine | Rackmount | not stated | $959.83 | Buy Now |
APC SMC1500 APC Smart-UPS 1500VA/900W Rackmount UPS, Line Interactive, SMC1500-2UC | 1500 VA | 900 W | pure sine | Rackmount | not stated | $790.50 | Buy Now |
APC SMC1500 APC 1500VA Smart UPS with SmartConnect, Rack Mount UPS Battery Backup, Sinewav | 1500 VA | 100 W | pure sine | Rackmount | USB | $795.50 | Buy Now |
Eaton SMC15002URM Eaton Tripp Lite SMC15002URM 1500VA Pure Sine Wave 2U Rack Mount UPS 1000W | 1500 VA | 1000 W | pure sine | Rackmount | USB, LCD | $801.10 | Buy Now |
Vertiv Vertiv-1500VA Vertiv Liebert PSI5-1500RT120 1500VA Battery Backup UPS Pure Sine Wave AVR | 1500 VA | 1350 W | pure sine | Rackmount | LCD | $749.99 | Buy Now |
Eaton Eaton-1500VA Eaton Tripp Lite SMART1500RMXL2U 1500VA UPS Extend Run Online Option 1440W | 1500 VA | 1440 W | pure sine | Rackmount | SNMP, LCD | $625.97 | Buy Now |
Eaton Eaton-1500VA Eaton Tripp Lite SMART1500RM2U SmartPro 1500VA Pure Sine Wave UPS 1350W AVR | 1500 VA | 1350 W | pure sine | Rackmount | USB, SNMP, LCD | $859.95 | Buy Now |
APC SMX1500RM2UNC APC Network UPS, 1500VA Smart-UPS Sine Wave UPS with Extended Run Option, SMX1 | 1500 VA | 1200 W | pure sine | Rackmount | SNMP | $993.00 | Buy Now |
APC SMX1500RM2UC APC Network UPS, 1500VA Smart-UPS Sine Wave UPS with Extended Run Option, SMX1 | 1500 VA | 1200 W | pure sine | Rackmount | not stated | $637.22 | Buy Now |
Eaton Eaton-1500VA Eaton Tripp Lite SMART1500RM2UN SmartPro 1500VA UPS Network Card 1350W AVR | 1500 VA | 1350 W | pure sine | Rackmount | SNMP, LCD | $1329.95 | Buy Now |
CyberPower PR1500RTXL2UN CyberPower PR1500RTXL2UN Smart App Sinewave UPS System, 1500VA/1500W, 8 Outlet | 1500 VA | 1500 W | pure sine | Rackmount | SNMP, LCD | $1350.00 | Buy Now |
CyberPower CyberPower-1500VA CyberPower OL1500RTXL2U Smart App Online UPS System, 1500VA/1350W, 8 Outlets, | 1500 VA | 1350 W | pure sine | Rackmount | LCD | $1395.95 | Buy Now |
APC SMT1500RM2UCNC APC 1500VA Smart UPS with SmartConnect and Network Card, SMT1500RM2UCNC, Rackm | 1500 VA | 1000 W | pure sine | Rackmount | SNMP | $1099.99 | Buy Now |
Vertiv Vertiv-1500VA Vertiv Liebert PSI5-1500RT120LIN Lithium-Ion UPS 1500VA AVR 2U w/ RDU120 | 1500 VA | 1350 W | pure sine | Rackmount | SNMP | $1794.99 | Buy Now |
CyberPower PR2200RTXL2UN CyberPower PR2200RTXL2UN Smart App Sinewave UPS System, 2200VA/2200W, 8 Outlet | 2200 VA | 2200 W | pure sine | Rackmount | SNMP, LCD | $1094.22 | Buy Now |
APC SMT2200RM2UC APC 2200VA Smart UPS with SmartConnect, SMT2200RM2UC Rack Mount UPS Battery Ba | 2200 VA | 1980 W | pure sine | Rackmount | not stated | $1012.38 | Buy Now |
CyberPower PR2200RT2U CyberPower PR2200RT2U Smart App Sinewave UPS System, 2200VA/2200W, 8 Outlets, | 2200 VA | 2200 W | pure sine | Rackmount | LCD | $1485.00 | Buy Now |
APC SMT3000RM2UC APC 3000VA UPS SMT3000RM2UC Rack Mount Sinewave Battery Backup Bundle | 3000 VA | 2700 W | pure sine | Rackmount | not stated | $1840.50 | Buy Now |
APC APC-3000VA APC 3000VA Lithium Ion UPS, SMTL3000RM2UC, Pure Sine Wave Rackmount UPS, 120V | 3000 VA | 2700 W | pure sine | Rackmount | LCD | $1999.00 | Buy Now |
APC SMX3000RMLV2U APC Network UPS, 3000VA Smart-UPS Sine Wave UPS with Extended Run Option, SMX3 | 3000 VA | 2700 W | pure sine | Rackmount | not stated | $2493.71 | Buy Now |
Eaton Eaton-3000VA Eaton Tripp Lite Series 3000VA Smart UPS Back Up, Sine Wave, Network Card Incl | 3000 VA | 2700 W | pure sine | Rackmount | LCD | $2749.00 | Buy Now |
APC APC-3000VA APC Smart-UPS 3000 VA Lithium Ion UPS, SMTL3000RMUCNC, Short Depth, Pure Sine | 3000 VA | 2700 W | pure sine | Rackmount | SNMP, LCD | $4055.60 | Buy Now |
10 in-stock listings · check the maker's datasheet before putting one of these in front of a server · VA, watts, waveform and outlet counts are the maker’s claims, read from the listing · refreshed every few hours
| Unit | VA | Watts | Waveform | Form | Comms | Price | |
|---|---|---|---|---|---|---|---|
Eaton 5P1500R Eaton 5P 1500 RACKMOUNT - UPS - 1100 Watt - 1440 VA (5P1500R) - | 1440 VA | 1100 W | not stated | Rackmount | not stated | $1182.07 | Buy Now |
Eaton SMART1500LCD Eaton Tripp Lite SMART1500LCD 1500VA 2U Rack Mount UPS 900W Battery Backup | 1500 VA | 900 W | not stated | Rackmount | LCD | $290.00 | Buy Now |
Eaton Eaton-1500VA Eaton 5P rackmount Compact 1500VA UPS | 1500 VA | 1100 W | not stated | Rackmount | USB, Serial | $949.95 | Buy Now |
Tripp Lite Tripp Lite-1500VA Tripp Lite SUINT1500LCD2U 1500VA 1350W Ups Smart Online Intl LCD Rackmount 208 | 1500 VA | 1350 W | not stated | Rackmount | USB, LCD | $1184.40 | Buy Now |
Eaton Eaton-1500VA Eaton Tripp Lite SUINT1500LCD2U 230V 1500VA Double-Conversion UPS 1350W | 1500 VA | 1350 W | not stated | Rackmount | LCD | $1215.66 | Buy Now |
Vertiv Vertiv-1500VA Vertiv Liebert PSI5-1500RM1201UN 1500VA UPS Battery Backup AVR 1U w/ RDU120 | 1500 VA | 1350 W | not stated | Rackmount | not stated | $1297.24 | Buy Now |
Vertiv Vertiv-1500VA Vertiv - GXT5-1500IRT2UXL - Vertiv Liebert GXT5 UPS - 1500VA/1500W 230V | Onli | 1500 VA | 1500 W | not stated | Rackmount | LCD | $1555.99 | Buy Now |
APC SMT3000RM2UC APC 3000VA Smart UPS with SmartConnect, SMT3000RM2UC Rack Mount UPS Battery Ba | 3000 VA | 2700 W | not stated | Rackmount | USB, Serial | $1820.00 | Buy Now |
APC SMX3000RMLV2U APC Smart-UPS X SMX3000RMLV2U 3000 VA Rack-mountable UPS. SMART UPS X 3000VA R | 3000 VA | 2700 W | not stated | Rackmount | LCD | $2381.99 | Buy Now |
Vertiv Vertiv-3000VA Vertiv Liebert PSI5-3000SRT120LI Lithium-Ion UPS 3000VA Battery Backup 2U | 3000 VA | 2700 W | not stated | Rackmount | not stated | $2494.99 | Buy Now |
Of the 36 in-stock units we track, 26 state an output waveform - 72%. Of those, 26 say pure sine and 0 say simulated. The remaining 10 say nothing at all.
The asymmetry is the finding. Pure sine is a selling point and gets printed; a stepped approximation is not and does not. So a silent listing is more likely to be the cheaper waveform than the better one, and we still do not claim to know which - we count it as unknown and tell you to check the datasheet.
A rackmount UPS is described by its height and constrained by its depth, and the product title only tells you the first. A 2U label says the unit occupies two rack units of vertical space. It says nothing about how far back it extends, and that is the measurement that decides whether it fits.
Full-depth server cabinets run around 1000mm and have room for essentially anything. A great many home and small-office racks - wall-mount enclosures, open frames, the short-depth cabinets sold for network gear - have usable depth in the region of 400 to 600mm, and a rackmount UPS built for a datacentre cabinet will simply not go in. The unit arrives, does not fit, and goes back at your expense.
The specification to look for is short depth, and vendors do build for it: QNAP and others publish explicit short-depth rackmount lines, and the server world uses the same phrase for chassis. Where a listing states its depth we render what it states. Where it does not, we render nothing rather than guessing, and the correct move is to measure the rails-to-rear clearance in your own rack before ordering.
The second physical constraint is weight and where it sits. These units are mostly battery, and a 2U unit can weigh more than the servers above it. It belongs at the bottom of the rack. Putting a heavy UPS high in a two-post open frame is how a rack ends up on the floor, and no amount of correct depth measurement helps with that.
Larger rackmount units frequently ship with a NEMA 5-20P plug rather than the ordinary 5-15P found on consumer equipment. These are physically different connectors - the 5-20P has one blade rotated 90 degrees - and a 5-20P will not go into a standard household outlet. That is a mechanical fact about the plug, not a subtlety.
Where a listing states its plug type we render it as that listing's statement of what the unit ships with, in the same column and with the same weight as any other maker claim on this site. Where a listing does not state it, we show nothing.
What this site does not do, anywhere, is tell you what circuit to put in. We publish no guidance about 20-amp circuits, no guidance about dedicated runs, no guidance about breaker sizing. That is an electrician's decision and a code question that varies by jurisdiction, and the gap between "this unit ships with a 5-20P plug" and "go and install a 20A circuit" is exactly the gap between reporting a fact and taking on a liability we are in no position to carry.
The same applies to load. A unit's output rating tells you what it can deliver; what your building's circuit can deliver is a separate question with a separate answer, and if the two conflict the answer is not on a storage price site.
Everything on the hub page about active PFC applies to rack equipment with more force, because there is essentially no such thing as a modern server power supply that is not active PFC. The hot-swap supplies in a PowerEdge or a ProLiant are high-efficiency switching units with active correction as a matter of course, and they are exactly the class of load that CyberPower's own documentation describes sine wave output as protecting - the feature that prevents "unexpected shutdowns or component stress for connected devices with Active PFC power supplies."
For a rack, then, the waveform question is not really a question. Pure sine or do not buy it, and treat a listing that declines to state its waveform as a listing to check on the maker's datasheet before spending anything.
There is a second-order effect worth knowing. Redundant server supplies are usually two units sharing a load, and they are designed to survive one input dying. That is protection against a failed supply or a failed feed, not against a failed transfer: if both supplies are on the same UPS and that UPS puts out a waveform the supplies do not like, redundancy buys nothing, because both halves see the same bad input at the same instant.
The other rack-specific consideration is inrush. A rack of servers restarting together draws far more at spin-up than at idle, and a UPS sized precisely to the running load will trip on the restart. This is a real constraint and we are deliberately not putting a multiplier on it, because we have not measured one - the honest version is to read your servers' own documented maximum draw rather than their typical draw, and size against that.
In a rack the USB cable stops being the obvious answer, because there are several machines and only one cable. The three options are the ones the vendors document.
USB to one machine, which then relays to the others over the network, is the cheapest and works exactly as it does for a NAS. QNAP's documentation describes network UPS slave mode against a server's IP address; TrueNAS's master and slave modes are the same idea; Synology's Network UPS Server relays to client machines on the local network.
SNMP over the network, where the UPS itself carries a management card and every machine queries it directly. QTS documents this as a first-class option alongside USB: connect the UPS to the same network as the NAS and give the NAS its IP address and community settings. This is the arrangement that scales, and it removes the single point of failure where the one machine holding the cable is also the one that crashed.
The management card is usually a separate purchase and it is not cheap relative to a small UPS. It is worth noting that Synology's own tested list contains several entries that are management cards rather than UPS units at all - the AP9630, the AP9640, the RMCARD205, a Modbus gateway - which tells you how routine the SNMP path is in this class of equipment.
The framing on the hub applies here too and is worth restating for rack buyers, because rack equipment invites the fantasy of riding out the outage. It is almost never the right goal at this scale. A rack of used enterprise gear drawing several hundred watts will empty any reasonably priced battery in minutes, and the units that genuinely deliver hours are a different product class at a different price with a different maintenance story.
What the UPS is buying you is an orderly stop. Enough time for the hypervisor to suspend or migrate guests, for the array to flush and unmount, for the database to close cleanly. That is a small number of minutes and the sizing follows from it.
The second thing it buys, and this is underrated, is protection from the mains being bad rather than absent. A line-interactive unit regulates voltage continuously without going to battery, which matters far more in practice than outage survival for anybody on a supply that sags when the air conditioning starts. Sags and surges do the slow damage; the total outage is just the dramatic one.
And the same caveat closes this page as closes the others: whatever you buy, pull the plug deliberately once and watch the whole chain work, before the day it has to.
The UPS hub has the waveform rule and the sizing arithmetic · Tower vs rackmount is the price comparison · Used servers, server parts and hot-swap PSUs are the equipment on the other end · rack noise is the other thing people underestimate about putting this gear indoors · the build calculator totals a rack build · UPS for a NAS covers the shutdown integration in detail.
Check the depth, not the U count. A 2U label describes height only. Full-depth server cabinets take anything; many home and small-office racks have far less usable depth and will not accept a unit built for a datacentre cabinet. Look for short-depth models if your rack is shallow, measure the rails-to-rear clearance before ordering, and where a listing does not state a depth, treat that as unknown rather than acceptable.
It is a 20-amp plug with one blade rotated 90 degrees relative to the ordinary 5-15P, which means it physically will not fit a standard household outlet. Larger rackmount units often ship with one. We render the plug type where a listing states it, as that listing's statement of what the unit ships with. We give no guidance at all about what circuit to install - that is an electrician's decision and a code question.
In practice yes. Modern hot-swap server supplies use active power factor correction essentially without exception, and that is precisely the load CyberPower's own documentation describes sine wave output as protecting - preventing unexpected shutdowns or component stress. Redundant supplies do not help here: if both are on the same UPS they both see the same output at the same moment, so redundancy protects against a failed feed, not a bad waveform.
At the bottom. These units are mostly lead-acid battery and a 2U unit can outweigh the servers above it. Mounting that mass high in a two-post frame is a structural problem regardless of how carefully you checked the depth.
SNMP if you have more than a couple of machines and can justify the management card. It lets every machine query the UPS directly and removes the failure mode where the one machine holding the USB cable is also the one that went down. USB to a single machine, relaying to the others over the network, is the cheap path and is documented by Synology, QNAP and TrueNAS alike. QTS documents both as first-class options.
Enough to stop cleanly, which is minutes. A rack of enterprise gear drawing several hundred watts empties an affordably priced battery quickly, and the units that genuinely deliver hours are a different product class at a different price. Size for an orderly shutdown - suspend the guests, flush and unmount the arrays, close the databases - and size against your servers' documented maximum draw rather than their typical draw, because a restart draws far more than idle.
Specification claims on this page were checked against the pages below on 4 August 2026. Where a widely-repeated figure did not survive that check, we report what the source says now and say so in the text rather than repeating the familiar number.