WD

My Cloud EX2 Ultra 16TB

WDBVBZ0160JCH-NESN
My Cloud EX2 Ultranas-device16TBGbEDesktop
Check Availability
Quick Verdict

The WD My Cloud EX2 Ultra 16TB is a 16TB GbE enterprise drive at $undefined/TB - Verify recording technology before use in RAID. New unit with full 2-year warranty.

Specifications

Capacity16TB
Form FactorDesktop
InterfaceGbE
Recording Tech
Sector Size
Workload Rating
Warranty2 years
ASINB01AWH05OG

90-Day Price History

Price history will appear here after 24 hours.

Check back tomorrow.

Frequently Asked Questions

This GbE cartridge requires a compatible GbE tape drive. GbE drives can also read the previous LTO generation.

BaFe (Barium Ferrite) tape media has an archival life of 30+ years when stored in controlled conditions (18-26°C, 20-50% humidity). Store tapes vertically and avoid magnetic fields.

Yes. LTO is an open standard. This cartridge works in any GbE-compatible standalone drive or automated tape library regardless of manufacturer.

Use Case Scenarios

🏠
Home & SMB NAS
Building a high-capacity NAS for media, backups and file sharing.
✓ Excellent fit
Verify CMR recording before using in RAID. New drives come with full warranty.
💾
Backup Server / Veeam Target
Dedicated backup storage for Veeam, Commvault, or NetBackup.
✓ Excellent fit
16TB SATA drives are ideal for backup targets. SATA gives maximum $/TB for backup repositories.
☁️
Object Storage / Cold Data Tier
High-density storage for MinIO, Ceph or Hadoop at scale.
✓ Excellent fit
At 16TB per drive, a 60-bay JBOD delivers 960TB raw — enough for petabyte-scale object storage.

Maintenance & Troubleshooting

Maintenance Checklist

On installCheck SMART baseline on arrival
Run smartctl -a /dev/sdX and record: Reallocated_Sector_Ct, Power_On_Hours, Spin_Retry_Count. Establishes baseline for future comparison.
MonthlyRun SMART short self-test
smartctl -t short /dev/sdX — takes 1-2 minutes, catches most developing issues. Schedule during off-peak.
QuarterlyRun SMART long self-test
smartctl -t long /dev/sdX — full surface scan, takes 8 hours for 16TB. Any test failure is grounds for immediate replacement.
QuarterlyCheck RAID array health
Verify no degraded drives. A degraded array with no hot spare is one failure from data loss. Check mdstat or controller UI.
AnnuallyVerify drive firmware version
Check WD support site for firmware updates. Some versions have known bugs affecting integrity.
Every 3-5 yearsPlan proactive replacement
Enterprise HDDs have higher failure rates after year 4-5. At 16TB per drive, budget for replacements before failures occur.

Troubleshooting Guide

Cause: Loose SATA data or power cable, failed port, or drive not spinning up.
Fix: Reseat both cables. Try a different port. Listen for spin-up sound. Test with a known-good cable.